Skip to main content

Quantum Offline Software V2242

Release Date: June 2026

Download Links

Quantum 112 Quantum 225 Quantum 326 & 338 Quantum 5 Quantum 7 Quantum 852

 

For users who wish to use console extension packages such as Theatre, Broadcast, Pulse, or SD12-96, please install the offline editor for the relevant console type. Then navigate to System > Enable Extensions, select the desired extension, and restart the application to activate it.

 

Key New Features

  • Setlists – Smarter Snapshot Control - Easily organise and filter snapshots without duplicating them, allowing more efficient show management and flexibility during live operation.
  • Aux to Faders Enhancements - Group faders can now be included when assigning aux sends to faders, providing improved workflow and control.
  • Mustard Levelling Amp - A new compressor inspired by classic tube designs, delivering warmth and dynamic control ideal for vocals and bass.
  • Snapshot Recall Improvements - Capture and update recall times using timecode, with added flexibility for offset adjustments. Move and reorder snapshots and macros with ease, Enhanced metering and system diagnostics visibility.
  • A new Collect Diagnostics tool simplifies gathering logs and session data for support cases, helping resolve issues faster and more efficiently.
  • Sound Devices Integration - Expanded visibility and control with real-time RF data, battery status, and audio monitoring directly from the console.
  • LiveTrax 3 Integration - Enhanced recording workflow with marker automation via snapshots, playback-linked snapshot recall. New macro controls for recording and navigation.

Errors Fixed

  • SD7 & Q7 bridge screen brightness value was not loaded with session file if it was all the way down 
  • Aux Nodes were not always indicating the correct status when "safe" 
  • Console was intermittently sending wrong mapping information to Klang 
  • Intermittent issues when selecting Mustard on an LCR buss or larger. 
  • Loading a template session was not sending the session name to KLANG 
  • Onscreen LCDs on Q8 did not always draw meters correctly when switching between unpopulated banks
  • Restructuring would default metering position options 
  • Disable master mute only worked if the left leg was the folded view channel 
  • 8 band EQ numbers were reversed in macros 
  • Occasionally, fourier plugin chains appeared as blank on the Q1 
  • Under-screen rotary LCD display did not always match the selected aux on Q8 
  • Q8 aux mixes on pan rotaries mismatch 
  • All pass filter in Expanded Channel Control sometimes drawn based on the wrong band after session load
  • Patching a matrix input changed the name of the matrix output on the Q8 meter bridge 
  • Issues on Q8 when saving exceptionally large session files 
  • Safe padlocks were still shown on onscreen LCDs on Q8 when Spice Rack control was on faders 
  • Enabling Waves external control or fourier integration was selecting wrong network adaptor by default on Q1
  • Q8 far right master fader was not reassigned on a default session 
  • DMI-Dante64@96 and DMI-OPTO in an Orange box could cause AVs 
Associated Documentation Downloads
No downloads for this article
Table of Contents

    Was this article helpful?

    1 out of 1 found this helpful